HomeMy WebLinkAboutOrdinance No. 09-1795 THE CITY OF THE COLONY, TEXAS ORDINANCE NO. 09-1795 AN ORDINANCE OF THE CITY OF THE COLONY, TEXAS AMENDING THE CODE OF ORDINANCES BY AMENDING CHAPTER 6, ARTICLE I, SECTION 6-5, BY DELETING ALL REFERENCES TO THE INTERNATIONAL PLUMBING CODE, 2003 EDITION, AND THE AMENDMENTS THERETO AND PROVIDING FOR THE ADOPTION OF THE INTERNATIONAL PLUMBING CODE, 2006 EDITION; PROVIDING AMENDMENTS TO THE INTERNATIONAL PLUMBING CODE, 2006 EDITION; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A REPEALING CLAUSE; PROVIDING A SAVINGS CLAUSE; PROVIDING A PENALTY FOR VIOLATION OF THIS ORDINANCE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF THE COLONY, TEXAS: SECTION 1. That the Code of Ordinances of the City of The Colony, Texas be, and the same is, hereby amended by amending Chapter 6, Article I, Section 6-5 by deleting all references to the International Plumbing Code, 2003 Edition and the amendments thereto and providing for the adoption the International Plumbing Code, 2006 Edition with the appendices, and the amendments thereto, which shall read as follows: "ARTICLE 1. IN GENERAL Sec. 6-5. Plumbing code - Adopted. (a) Adoption. The International Plumbing Code, 2006 Edition with the appendices, as published by the International Code Council is hereby adopted by reference. Unless deleted, amended, expanded or otherwise changed herein, all provisions of such code shall be fully applicable and binding. (b) Amendments. International Plumbing Code, 2006 Edition adopted and amended. Table of Contents, Chapter 7, Section 714; change to read asfollows: Section 714 Engineered Computerized Drainage Design . . . .. . . . . . . . . . . . . . . 65 Page 1 TM 33480.76.000 Section 102.8; change to read asfollows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 13 and such codes, when specifically adopted, and standards shall be considered as part of the requirements of this code to the prescribed extent of each such reference. Where the differences occur between provisions of this code and the referenced standards, the provisions of this code shall be the minimum requirements. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. Sections 106.6.2 and 106.6.3; change to read asfollows: 106.6.2 Fee schedule. The fees for all plumbing work shall be as indicated in the follo\ving schedule: (JURISDICTION TO INSERT }1PPROPRL^1TE SCHEDULE) adopted by resolution of the governing body of the jurisdiction. 106.6.3 Fee Refunds. The code official shall establish a policy for authorize authorizing the refunding of fees as follows. (Delete balance of section) Section 109; delete. Section 305.6.1; change to read asfollows.' 305.6.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of [number] inches (mm) belo'...' finished grade at the point of septic tank connection. Building sewers shall be a minimum of 12 inches (304 mm) below grade. Section 305.9; change to read asfollows.' 305.9 Protection of components of plumbing system. Components of a plumbing system installed within 3 feet along alleyways, driveways, parking garages or other locations in a manner in which they would be exposed to damage shall be recessed into the wall or otherwise protected in an approved manner. Sections 312.9.1 and 312.9.2; change to read as follows: 312.9.1 Inspections. Annual inspections shall be made of all backflow prevention assemblies and air gaps to determine whether they are operable. In the absence of local provisions, the owner is responsible to ensure that testing is performed. Page 2 TM 33480.76.000 312.9.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies, pressure vacuum breaker assemblies, reduced pressure detector fire protection backflow prevention assemblies, double check detector fire protection backflow prevention assemblies, hose connection backflow preventers, and spill-proof vacuum breakers shall be tested at the time of installation, immediately after repairs or relocation and at least annually. The testing procedure shall be performed in accordance with applicable local provisions. In the absence of local provisions, the owner is responsible to ensure that testing is done in accordance with one of the following standards: {list of standards unchanged} Section 314.2.1; modify second sentence to read asfollows.' 314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Condensate shall not discharge into a street, alley, sidewalk, rooftop, or other areas so as to cause a nmsance. Section 314.2.2; change to read asfollows.' 314.2.2 Drain pipe materials and sizes. Components of the condensate disposal system shall be cast iron, galvanized steel, copper, cross-linked polyethylene, polybutylene, polyethylene, ABS, CPVC, or schedule 80 PVC pipe or tubing when exposed to ultra violet light. All components shall be selected for the pressure, aHd--temperature and exposure rating of the installation. Condensate waste and drain line size shall not be less than %-inch (19 mm) internal diameter and shall not decrease in size from the drain pan connection to the place of condensate disposal. Where the drain pipes from more than one unit are manifolded together for condensate drainage, the pipe or tubing shall be sized in accordance with an approved method. All horizontal sections of drain piping shall be installed in uniform alignment at a uniform slope Section 401.1; add a sentence to read asfollows: The provisions of this Chapter are meant to work in coordination with the provisions of the Building Code. Should any conflicts arise between the two chapters, the Code Official shall determine which provision applies. Section 403.1; change to read asfollows: 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number as follows: 1. Assembly Occupancies: At least one drinking fountain shall be provided at each floor level in an approved location. Page 3 TM 33480.76.000 Exception: A drinking fountain need not be provided in a drinking or dining establishment. 2. Groups A, B, F, H, I, M and S Occupancies: Buildings or portions thereof where persons are employed shall be provided with at least one water closet for each sex except as provided for in Section 403.2. 3. Group E Occupancies: Shall be provided with fixtures as shown in Table 403.1. 4. Group R Occupancies: Shall be provided with fixtures as shown in Table 403.1. It is recommended, but not required, that the minimum number of fixtures provided also comply with the number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Add Section 403.1.2 to read as follows: 403.1.2 Finish material. Finish materials shall comply with Section 1209 of the International Buildinf? Code. Section 405.6; delete. Section 409.2; change to read as follows: 409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected against backflow by an air gap or backflow preventer in accordance with Section 608. Page 4 TM 33480.76.000 Section 410.1; change to read asfollows: 410.1 Approval. Drinking fountains shall conform to ASME A112.19.1M, ASME A112.19.2M or ASME A112.19.9M, and water coolers shall conform to ARI 1010. Drinking fountains and water coolers shall conform to NSF 61, Section 9. 'Nhere water is served in restaurants or '""here bottled water coolers are pro':ided in other occupancies, drinking fountains shall not be required. In other occupancies, 'Nhere drinking fountains are required, bottled ""ater dispensers shall be permitted to be substituted for not more than 50 percent of the required drinking fountains. Exception: A drinking fountain need not be provided in a drinking or dining establishment. Section 412.4; change to read asfollows.' 412.4 Required location Pablic laandries and eentral washing faeilities. Floor drains shall be installed in the following areas. 1. In public coin-operated laundries and in the central washing facilities of multiple family dwellings, the rooms containing automatic clothes washers shall be provided with floor drains located to readily drain the entire floor area. Such drains shall have a minimum outlet of not less than 3 inches (76 mm) in diameter. 2. Commercial kitchens. (In lieu of floor drains in commercial kitchens, the code official may accept floor sinks.) Section 413.4; change to read asfollows: 413.4 Water supply required. All food waste grinders shall be provided with a supply of cold water. The water supply shall be protected against backflow by an air gap or with the installation of a backflow preventer in accordance with Section 608. Section 417.5; change to read asfollows.' 417.5 Shower floors or receptors. Floor surfaces shall be constructed of impervious, noncorrosive, nonabsorbent and waterproof materials. Thresholds shall be a minimum of 2 inches (51 mm) and a maximum of 9 inches (229 mm), measured from top of the drain to top of threshold or dam. Thresholds shall be of sufficient width to accommodate a minimum twenty-two (22) inch (559 mm) door. Exception: Showers designed to comply with ICC/ANSI A117.1. Section 417.5.2; change to read asfollows.' 417.5.2 Shower lining. Floors under shower compartments, except where prefabricated receptors have been provided, shall be lined and made water tight utilizing material Page 5 TM 33480.76.000 complying with Sections 417.5.2.1 through 417.5.2.4. Such liners shall turn up on all sides at least 2- J inches (M 76 mm) above the finished threshold level and shall extend outward over the threshold and fastened to the outside of the threshold iamb. Liners shall be recessed and fastened to an approved backing so as not to occupy the space required for wall covering, and shall not be nailed or perforated at any point less than 1 inch (25 mm) above the finished threshold. Liners shall be pitched one-fourth unit vertical in 12 units horizontal (2-percent slope) and shall be sloped toward the fixture drains and be securely fastened to the waste outlet at the seepage entrance, making a water-tight joint between the liner and the outlet. Add Section 417.7 to read asfollows.' 417.7 Test for shower receptors. Shower receptors shall be tested for water tightness by filling with water to the level of the rough threshold. The drain shall be plugged in a manner so that both sides of pans shall be subiected to the test at the point where it is clamped to the drain. Section 419.3; change to read asfollows.' 419.3 Surrounding material. Wall and floor space to a point 2 feet (610 mm) in front of a urinal lip and 4 feet (1219 mm) above the floor and at least 2 feet (610 mm) to each side of the urinal shall be waterproofed with a smooth, readily cleanable, hard, nonabsorbent material. Section 502.3; change to read asfollows.' 502.3 Water heaters installed in attics. Attics containing a water heater shall be provided with an opening and unobstructed passageway large enough to allow removal of the water heater. The passageway shall not be less than 30 inches (762 mm) high and 22 inches (559 mm) wide and not more than 20 feet (6096 mm) in length when measured along the centerline of the passageway from the opening to the water heater. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) wide. A level service space at least 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the water heater. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm) , or larger where such dimensions are not large enough to allow removal of the water heater. Add Section 502.5 to read asfollows.' 502.5 Water heaters above e:round or floor. When the attic, roof. mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. Page 6 TM 33480.76.000 Exception: A max 10 gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and a water heater is installed is not more than ten (0) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. 502.5.1 Whenever the mezzanine or platform is not adequately lighted or access to a receptacle outlet is not obtainable from the main level, lighting and a receptacle outlet shall be provided in accordance with Section 502.1. Section 504.6; change to read asfollows: 504.6 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system. 2. Discharge through an air gap. located in the same room as the water fleatef . 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufactures installation instructions and installed with those instruction.. 5. Discharge to the floor, to an indirect waste receptor or to the outdoors. Where discharging to the outdoors in areas subject to freezing, discharge piping shall be first piped to an indirect waste receptor through an air gap located in a conditioned area. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is readily observable by the building occupants. 8. Not be trapped. 9. Be installed so as to flow by gravity. 10. Not terminate less than 6 inches or more than 24 inches (152 mm) above grade the floor ef nor more than 6 inches above the waste receptor. 11. Not have a threaded connection at the end of such piping. 12. Not have valves or tee fittings. Page 7 TM 33480.76.000 13. Be constructed of those materials listed in Section 605.4 or materials tested, rated and approved for such use in accordance with ASME AI12.4.1. Add Section 604.4.1 to read as follows: 604.4.1 State maximum flow rate. Where the State mandated maximum flow rate is more restrictive than those of this section, the State flow rate shall take precedence. Tables 605.3 and 605.4; delete "Polybutylene (PR) plastic pipe and tubing". Section 606.1; delete items #4 and #5. Section 606.2; change to read as follows.. 606.2 Location of shutoff valves. Shutoff valves shall be installed in the following locations: 1. On the fixture supply to each plumbing fixture other than bathtubs and showers in one- and two-family residential occupancies, and other than in individual sleeping units that are provided with unit shutoff valves in hotels, motels, boarding houses and similar occupancies. 2. On the water supply pipe to each sillcock. J.2 On the water supply pipe to each appliance or mechanical equipment. Section 608.1; change to read asfollows.' 608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to prevent contamination from nonpotable liquids, solids or gases being introduced into the potable water supply through cross-connections or any other piping connections to the system. Backflow preventer applications shall conform to applicable local regulations, Table 608.1, except and as specifically stated in Sections 608.2 through 608.16.10. Section 608.16.5; change to read asfollows.' 608.16.5 Connections to lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker, a double-check assembly or a reduced pressure principle backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principle backflow preventer. Page 8 TM 33480.76.000 Section 608.17; change to read asfollows.' 608.17 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with applicable local regulations. In the absence of other local regulations, installation shall be in accordance with Sections 608.17.1 through 608.17.8. Section 610.1; add exception to read asfollows.' 610.1 General. New or repaired potable water systems shall be purged of deleterious matter and disinfected prior to utilization. The method to be followed shall be that prescribed by the health authority or water purveyor having jurisdiction or, in the absence of a prescribed method, the procedure described in either A WW A C651 or A WW A C652, or as described in this section. This requirement shall apply to "on-site" or "inplant" fabrication of a system or to a modular portion of a system. 1. The pipe system shall be flushed with clean, potable water until dirty water does not appear at the points of outlet. 2. The system or part thereof shall be filled with a water/chlorine solution containing at least 50 parts per million (50 mg/L) of chlorine, and the system or part thereof shall be valved off and allowed to stand for 24 hours; or the system or part thereof shall be filled with a water/chlorine solution containing at least 200 parts per million (200 mg/L) of chlorine and allowed to stand for 3 hours. 3. Following the required standing time, the system shall be flushed with clean potable water until the chlorine is purged from the system. 4. The procedure shall be repeated where shown by a bacteriological examination that contamination remains present in the system. Exception: With prior approval the Code Official may waive this requirement when deemed un-necessary by the Code Official. Add Section 712.5 to read as follows.' 712.5 Dual Pump System. All sumps shall be automatically discharged and, when in any "public use" occupancy where the sump serves more than 10 fixture units, shall be provided with dual pumps or eiectors arranged to function independently in case of overload or mechanical failure. For storm drainage sumps and pumping systems, see Section 1113. Section 714, 714.1; change to read asfollows.' SECTION 714 ENGINEERED C01\fPUTERIZED DRAINAGE DESIGN 714.1 Design of drainage system. The sizing, design and layout of the drainage system shall be permitted to be designed by approved computer design methods. Page 9 TM 33480.76.000 Section 802.1.6; amended sentence to read asfollows.' 802.1.6 Domestic dishwashing machines. Domestic dishwashing machines shall discharge indirectly through an air gap or air break into a standpipe or waste receptor in accordance with Section 802.2, or discharge into a wye-branch fitting on the tailpiece of the kitchen sink or the dishwasher connection of a food waste grinder. The waste line of a domestic dishwashing machine discharging into a kitchen sink tailpiece or food waste grinder shall connect to a deck-mounted air gap. or the 'Naste line shall riso and be securely fastonod to tho underside of the sink rim or counter. Section 802.4; add a sentence to read asfollows.' No standpipe shall be installed below the ground. Section 904.1; changed to read asfollows.' 904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least six (6) inches (152 mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. Section 906.1; changed to read asfollows.' 906.1 Distance of trap from vent. Each fixture trap shall have a protecting vent located so that the slope and the developed length in the fixture drain from the trap weir to the vent fitting are within the requirements set forth in Table 906.1. Exception: The developed length of the fixture drain from the trap '.veir to the vent fitting for self siphoning fixtures, such as '.vater closets, shall not be limited. Section 912.1; change to read as follows: 912.1 Type of fixture. A combination drain and vent system shall not serve fixtures other than floor drains, sillies, lavatories, and drinking fountains standpipes, and indirect waste receptors. Combination drain and vent systems shall not receive the discharge from a food waste grinder or clinical sink. Section 1002.10; delete. Section 1003.3.4.1; change to read asfollows: 1003.3.4.1 Grease Interceptor Capacity. Grease interceptors shall have a minimum 1,000 gallon grease retention capacity. Page 10 TM 33480.76.000 Section 1101.8; change to read asfollows.' 1101.8 Cleanouts required. Cleanouts shall be installed in the building storm drainage system and shall comply with the provisions of this code for sanitary drainage pipe cleanouts. Exception: Subsurface drainage system Section 1106.1; change to read asfollows: 1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers, and any horizontal branches of such drains or sewers shall be based on six (6) inches per hour the 100 year hourly rainfall rate indicated in Figure 1106.1 or on other rainfall rates determined from approved local v:eather data. Section 1107.3; change to read asfollows.' 1107.3 Sizing of secondary drains. Secondary (emergency) roof drain systems shall be sized in accordance with Section 1106 based on the rainfall rate for v:hich the primary system is sized in Tables 1106.2, 1106.3 and 1106.6. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by Section 1101.7. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when sizing the secondary roof drain system. Section 1202.1; delete Exception 2. SECTION 2. If any section, subsection, paragraph, sentence, phrase or work in this ordinance, or application thereof to any person or circumstance is held invalid by any court of competent jurisdiction, such holding shall not affect the validity of the remaining portions of this ordinance, and the City Council of the City of The Colony, Texas hereby declares it would have enacted such remaining portions despite any such invalidity. SECTION 3. That the repeal of any ordinance or any portion thereof by the preceding sections shall not affect or impair any act done or right vested or accrued or any proceeding, suit or prosecution had or commenced in any cause before such repeal shall take effect; but every such act done, or right vested or accrued, or proceedings, suit or prosecution had or commenced shall remain in full force and effect to all intents or purposes as if such ordinance or part thereof so repealed shall remain in force. SECTION 4. That any person, firm or corporation violating any of the provisions of this ordinance or the Code of Ordinances as amended hereby, shall be guilty of a misdemeanor and upon conviction in the Municipal Court of the City of The Colony, Texas, shall be subject to a fine not to exceed the sum of Two Thousand Dollars Page 11 TM 33480.76.000 ($2,000.00) for each offense; and each and every day such offense is continued shall constitute a new and separate offense. SECTION 5. That this ordinance shall become effective immediately from and after its passage and the publication of the caption, as the law and charter in such cases provide. PASSED AND APPROVED by the City Council of the City of The Colony, Texas, this the 19th day of January, 2009. ~ ~~!J~ Chris ie Wilson, City Secretary "' (SEAL) Roo Ii E. Hager City Attorney (REH/cdb 1/16/09) Page 12 r\1 n"):';11 -I, '''1'