HomeMy WebLinkAboutOrdinance No. 05-1623 CITY OF THE COLONY, TEXAS ORDINANCE NO. 05 - 05-1623 AN ORDINANCE OF THE CITY OF THE COLONY, TEXAS AMENDING THE CODE OF ORDINANCES BY AMENDING CHAPTER 6, ARTICLE I, SECTION 6-5.2, BY DELETING ALL REFERENCES TO THE INTERNATIONAL ENERGY CONSERVATION CODE, 2000 EDITION, AND THE AMENDMENTS THERETO AND PROVIDING FOR THE ADOPTION OF THE INTERNATIONAL ENERGY CONSERVATION CODE, 2003 EDITION; PROVIDING AMENDMENTS TO THE INTERNATIONAL ENERGY CONSERVATION CODE, 2003 EDITION; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A REPEALING CLAUSE; PROVIDING A SAVINGS CLAUSE; PROVIDING A PENALTY FOR VIOLATION OF THIS ORDINANCE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF THE COLONY, TEXAS: SECTION 1. That the Code of Ordinances of the City of The Colony, Texas be, and the same is, hereby amended by amending Chapter 6, Article I, Section 6-5.2 by deleting all references to the International Energy Conservation Code, 2000 Edition and the amendments thereto and providing for the adoption the International Energy Conservation Code, 2003 Edition, and the amendments thereto, which shall read as follows: "ARTICLE 1. IN GENERAL Sec. 6-5.2. International Energy Conservation Code, 2003 edition adopted and amended. (a) Adoption. The International Energy Conservation Code, 2003 Edition, as published by the International Code Council is hereby adopted by reference. Unless deleted, amended, expanded or otherwise changed herein, all provisions of such code shall be fully applicable and binding. (b) Amendments. Add the following section: Page 1 79781 101.4.1.3 Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Section 302.1; replace blank table 302.1 Exterior Design Conditions with the following: CONDITIONS VALUE Winter a, design dry-bulb (Op) (99.6%) 17 Summer a, design dry-bulb (OP) (0.4%) 100 Summer a, design wet-bulb (Op) (0.4%) 78 Degree days heating b 2407 Degree days cooling b 2603 Climate zone C 5B Delete note "a" and replace with the following: a. These values are from ASHRAE Handbook of Pun dam enta Is for Dallas/Ft. Worth International Airport 99.6% Winter DB, 0.4% Summer DB, and 0.4% Summer WB; and from Local Climatological Data for Dallas-Pt. Worth published by the National Climatic Data Center, National Oceanic and Atmospheric Administration. These values are for purpose of providing a uniform basis of requirements for North Central Texas. This will not preclude licensed professionals form submitting design analyses based on site measurements or published data more specific to the building site. Adjustments shall be permitted to reflect local climates which differ from the tabulated values, or local weather experience determined by the code official. Section 502.1.1; delete exception #2 and substitute with following: 2.Buildings located in Climate Zones 5B Section 502.1.5; add the following exceptions: Exceptions: 1. Any glazing facing within 45 degrees of true north; 2. Any glazing facing within 45 degrees of true south which is shaded along its full width by a permanent overhang with a projection factor of 0.3 or greater. 3. Any fenestration with permanently attached screens where the screens have a rated shading coefficient of .6 or less. Page 2 79781 Section 502.2; replace blank Table 502.2 Heating and Cooling Criteria with the following: Table 502.2 a,g HEATING AND COOLING CRIERIA Element Mode Detached One- Detached Two- Family Dwellings Family Dwellings Uo Uo Walls Heating or cooling 0.15 0.22 Roof / Ceiling Heating or cooling 0.03 0.03 Floors over Heating or cooling 0.05 0.05 unheated spaces Heated slab on Heating R-value = 6 R-value = 6 grade Unheated slab on Heating R-value = 0 R-value = 0 grade Basement walls Heating or cooling U-factor = 0.15 U-factor= 0.15 Craw 1 space walls Heating or cooling U-factor = 0.15 U-factor = 0.15 Delete Note 'a' and replace with the following: a. The above values have been determined for all counties in the North Central Texas Council of Governments region. Add Note "g": g. These requirements apply only to the boundaries of conditioned space. Air conditioning equipment and ductwork is recommended, but not required, to be located within the conditioned space in North Central Texas zones. Delete Figures 502.2 (1-6) Section 502.2; add note to Figure 502.2(7): All counties within the North Central Texas Council of Governments region are designated as within the area of very heavy termite infestation probability for purpose of uniform interpretation of this requirement. Section 502.2.2; add a second paragraph as follows: A building demonstrating envelope compliance at least 10% better than code may utilize R6 duct insulation in both supply and return air ducts in lieu of the insulation required by Table 503.3.3.3. Section 502.2.4; delete prescriptive Tables 502.2.4 (1-9) and substitute the following: Page 3 79781 Replace Tables 502.2.4 (1-6) with: Table 502.2.4 (1) Prescriptive Building Envelope Requirements, Detached One-Family Dwellings, Based on Window Area as a Percent of Gross Exterior Wall Area % Maximum Minimum Glazing Glazing Ceiling Exterior Floor Basement Slab Crawl U - factor R-value wall R-value wall perimeter space R-value R-value R-value wall and depth R-value <8% 0.70 R-26 R-ll R-ll R-5 R-O R-6 < 12% 0.65 R-26 R-13 R-ll R-5 R-O R-5 < 15% 0.60 R-30 R-13 R-19 R-6 R-O R-7 < 18% 0.52 R-30 R-13 R-19 R-6 R-O R-7 <20% 0.50 R-38 R-13 R-19 R-6 R-O R-7 <25% 0.46 R-38 R-16 R-19 R-6 R-O R-7 Replace Table 502.2.4 (7-9) with: Table 502.2.4 (2) Prescriptive Building Envelope Requirements, Detached Two-Family Dwellings, Based on Window Area as a Percent of Gross Exterior Wall Area % Maximum Minimum Glazing Glazing Ceiling Exterior Floor Basement Slab Crawl U - factor R-value wall R-value wall perimeter space R-value R-value R-value wall and depth R-value <20% 0.55 R-30 R-13 R-ll R-5 R-O R-5 <25% 0.55 R-30 R-13 R-ll R-5 R-O R-5 <30% 0.47 R-38 R-13 R-19 R-7 R-O R-8 Table 503.3.3.1 Minimum Pipe Insulation. Amend footnote "a" to read as follows: a. For piping lengths in excess of five (5) feet exposed to outdoor air, increase the insulation thickness by 0.5 inches. Table 503.3.3.3; add footnote "e" as follows: e. See Section 502.2.2 Section 503.3.3.4.3; change first sentence to read as follows: 503.3.3.4.3 Sealing required. All joints, longitudinal and transverse seams, and connections in ductwork, shall be made substantially airtight by means of welds, Page 4 79781 gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes or other approved closure systems. Tapes and mastics used to seal ductwork shall be listed and labeled in accordance with UL 18IA or UL 18IB. Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened. Unlisted duct tape is not permitted as a sealant on any metal ducts. Section 602.1.6; delete last sentence of exception. Section 602.2 Maximum solar heat gain coefficient for fenestration products. Add the following exceptions: Exceptions: 1. Any glazing facing within 45 degrees of true north; 2. Any glazing facing within 45 degrees of true south which is shaded along its full width by a permanent overhang with a projection factor of 0.3 or greater. 3. Any fenestration with attached screens where the screens have a rated shading coefficient of .6 or less. Section 802.2; replace blank tables 802.2 (1-4) with the completed tables provided on the following four pages. Delete Tables 802.2 (5-37). The deleted tables are not necessary after tables 1-4 are completed and eliminates data irrelevant to the NCTCOG region. TABLE 802.2(1) BUILDING ENVELOPE REQUIREMENTS WINDOW AND GLAZED DOOR AREA 10 PERCENT OR LESS OF ABOVE- GRADE WALL AREA ELEMENTS CONDITION / VALUE Skylights (U-factor) 1 Slab or below-grade wall (R- R-O value) Windows and glass doors SHGC U-factor PF< 0.25 Any Any 0.25 :S PF < 0.50 Any Any PF > 0.50 Any Any Roof assemblies (R-value) Insulation Continuous Insulation between framing All-wood joist / truss R-I9 R-I6 Metal joist / truss R-25 R-I7 Concrete slab or deck NA R-I6 Metal purlin with thermal block R-25 R-I7 Metal purlin without thermal X R-I7 block Page 5 79781 Floor over outdoor air or Insulation Continuous Insulation unconditioned space (R-value) between framing All-wood joist / truss R-ll R-6 Metal joist / truss R-ll R-6 Concrete slab or deck NA R-6 Above-grade walls (R-value) No framing Metal framing Wood framing Framed R-value cavity NA R-ll R-ll R-value continuous NA R-O R-O CMU, ~8 in., with integral insulation R-value cavity NA R-O R-O R-value continuous R-O R-O R-O Other masonry walls R-value cavity NA R-O R-O R-value continuous R-O R-O R-O TABLE 802.2(2) BUILDING ENVELOPE REQUIREMENTS WINDOW AND GLAZED DOOR AREA OVER 10 PERCENT BUT NOT GREATER THAN 25 PERCENT OF ABOVE-GRADE WALL AREA ELEMENTS CONDITION / VALUE Skylights (U-factor) 1 Slab or below-grade wall (R- R-O value) Windows and glass doors SHGC U-factor PF< 0.25 0.6 Any 0.25 :S PF < 0.50 0.7 Any PF :::: 0.50 Any Any Roof assemblies (R-value) Insulation Continuous Insulation between framing All-wood joist / truss R-25 R-19 Metal joist / truss R-25 R-20 Concrete slab or deck NA R-19 Metal purlin with thermal block R-30 R-20 Metal purl in without thermal X R-20 block Floor over outdoor air or Insulation Continuous Insulation unconditioned space (R-value) between framing All-wood joist / truss R-ll R-6 Metal joist / truss R-ll R-6 Concrete slab or deck NA R-6 Above-grade walls (R-value) No framing Metal framing T Wood Page 6 79781 framing Framed R-value cavity NA R-ll R-ll R-value continuous NA R-O R-O CMU, ::::: 8 in., with integral insulation R-value cavity NA R-ll R-Il R-value continuous R-5 R-O R-O Other masonry walls R-value cavity NA R-ll R-ll R-value continuous R-5 R-O R-O TABLE 802.2(3) BUILDING ENVELOPE REQUIREMENTS WINDOW AND GLAZED DOOR AREA OVER 25 PERCENT BUT NOT GREATER THAN 40 PERCENT OF ABOVE-GRADE WALL AREA ELEMENTS CONDITION / VALUE Skylights (U-factor) 1 Slab or below-grade wall (R- R-O value) Windows and glass doors SHGC U - factor PF< 0.25 0.4 0.7 0.25 .:::; PF < 0.50 0.5 0.7 PF> 0.50 0.6 0.7 Roof assemblies (R-value) Insulation Continuous Insulation between framing All-wood joist / truss R-25 R-19 Metal joist / truss R-25 R-20 Concrete slab or deck NA R-19 Metal purlin with thermal block R-30 R-20 Metal purlin without thermal X R-20 block Floor over outdoor air or Insulation Continuous Insulation unconditioned space (R-value) between framing All-wood joist / truss R-ll R-6 Metal joist / truss R-ll R-6 Concrete slab or deck NA R-6 Above-grade walls (R-value) No framing Metal framing Wood framing Framed R-value cavity NA R-l1 R-ll R-value continuous NA R-O R-O CMU, ::::: 8 in., with integral insulation Page 7 79781 R-value cavity NA R-ll R-ll R-value continuous R-5 R-O R-O Other masonry walls R-value cavity NA R-ll R-ll R-value continuous R-5 R-O R-O TABLE 802.2(4) BUILDING ENVELOPE REQUIREMENTS WINDOW AND GLAZED DOOR AREA OVER 40 PERCENT BUT NOT GREATER THAN 50 PERCENT OF ABOVE-GRADE WALL AREA ELEMENTS CONDITION / VALUE Skylights (U-factor) 1 Slab or below-grade wall (R- R-O value) Windows and glass doors SHGC U - factor PF< 0.25 0.4 0.7 0.25 ::s PF < 0.50 0.5 0.7 PF 2: 0.50 0.6 0.7 Roof assemblies (R-value) Insulation Continuous Insulation between framing All-wood joist / truss R-25 R-19 Metal joist / truss R-25 R-20 Concrete slab or deck NA R-19 Metal purlin with thermal block R-30 R-20 Metal purlin without thermal R-38 R-20 block Floor over outdoor air or Insulation Continuous Insulation unconditioned space (R-value) between framing All-wood joist / truss R-ll R-6 Metal joist / truss R-ll R-6 Concrete slab or deck NA R-6 Above-grade walls (R-value) No framing Metal framing Wood framing Framed R-value cavity NA R-13 R-ll R-value continuous NA R-3 R-O CMU, 2: 8 in., with integral insulation R-value cavity NA,NA R-ll R-ll R-value continuous R-5 R-O R-O Other masonry walls R-value cavity NA R-ll R-ll R-value continuous R-5 R-O R-O Page 8 79781 Add footnote "/" to SHOC column heading in Tables 802.2 (2), 802.2 (3), and 802.2 (4) to read as follows: f. Minimum SHGC requirements do not apply to glazing as follows: 1. Any glazing facing within 45 degrees oftrue north; 2. Any glazing facing within 45 degrees of true south which is shaded along its full width by a permanent overhang with a projection factor of 0.30 or greater. 3. Any glazing with permanent attached screens where the screens have a rated shading coefficient of 0.60 or less. Section 805.2.1 Interior Lighting Controls; add a third sentence to read: Large spaces shall have a separate switch or control for each 2500 square feet of floor area. Delete Figures 902.1 (1-43,45-51). There is no need to reference maps from other states. Chapter 10; replace referenced standard as follows: ASHRAE / IES - 00 Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings - 1999 Edition Chapter 10 - Referenced Standards: Under the heading ASHRAE and IESNA, change the Standard Reference Number from 90.1 -2001 to 90.1 - 1999." " SECTION 2. If any section, subsection, paragraph, sentence, phrase or work in this ordinance, or application thereof to any person or circumstance is held invalid by any court of competent jurisdiction, such holding shall not affect the validity of the remaining portions of this ordinance, and the City Council of the City of The Colony, Texas hereby declares it would have enacted such remaining portions despite any such invalidity. SECTION 3. That the repeal of any ordinance or any portion thereof by the preceding sections shall not affect or impair any act done or right vested or accrued or any proceeding, suit or prosecution had or commenced in any cause before such repeal shall take effect; but every such act done, or right vested or accrued, or proceedings, suit or prosecution had or commenced shall remain in full force and effect to all intents or purposes as if such ordinance or part thereof so repealed shall remain in force. SECTION 4. That any person, firm or corporation violating any of the provisions of this ordinance or the Code of Ordinances as amended hereby, shall be Page 9 79781 guilty of a misdemeanor and upon conviction in the Municipal Court of the City of The Colony, Texas, shall be subject to a fine not to exceed the sum of Two Thousand Dollars ($2,000.00) for each offense; and each and every day such offense is continued shall constitute a new and separate offense. SECTION 5. That this ordinance shall become effective immediately from and after its passage and the publication of the caption, as the law and charter in such cases provide. PASSED AND APPROVED by the City Council of the City of The Colony, Texas, this the 5th day of December, 2005. (!t . ~~.f. L- !~Jk . stie Wilson, City Secretary '-., ,~\~ ;> f .,'i '.,:\ S f ~ t! bi [V ~., f\:r' ,~~"-~ ~ j ,\ ~(i;$/ "i'"'i'~G:r:J;:P" Page 1 0 79781